* 1. The default depends on the MxC capacity. The value for a 200 V class MxC of 5.5 kW is given.
* 2. The setting range is from 10% to 200% of the MxC rated output current. The value for a 200 V class MxC for 5.5 kW is given.
* 3. If a multi-function input is set for motor 2 (H1-†† = 16), the setting range will depend upon the MxC capacity. The value for a 200 V class MxC of 5.5 kW is

given.

E4-04

Motor 2 Number
of Poles

Sets the number of poles of motor 2. This
value is automatically set during Auto-
Tuning.

2 to 48 4 poles

No

No

No

A

324H

-

Number of Poles

E4-05

Motor 2 Line-to-
Line Resistance

Sets the phase-to-phase resistance of
motor 2 in ohms. This value is automati-
cally set by the Auto-Tuning.

0.000 to

65.000

0.399

Ω

*1

No

A

A

A

325H

-

Term Resistance

E4-06

Motor 2 Leakage
Inductance

Sets the voltage drop due to motor leak-
age inductance as a percentage of rated
voltage of motor 2. This value is automat-
ically set during Auto-Tuning.

0.0 to

40.0

18.2%

*1

No

No

A

A

326H

-

Leak Inductance

E4-07

Motor 2 Rated
Output

Sets the rated power of motor 2 in kilo-
watts (kW). This value is automatically
set during Auto-Tuning.

5.50 to
650.00

5.50

kW

*1

No

A

A

A

327H

-

Mtr Rated Power

Parameter

Number

Name

Description

Setting

Range

Default

Change

during

Run

Control

Methods

MEMO-

BUS

Register

Page

Display

V/f

Open

Loop

Vector

Flux