U1-27

Output voltage ref-
erence (Vd)

Monitors the MxC internal volt-
age reference for motor excitation
current control.

10 V: 200 VAC (400 VAC)
(

−10 V to + 10 V possible)

0.1

VAC

No

A

A

5AH

Voltage Ref (Vd)

U1-28

Software No.
(CPU)

(Manufacturer’s CPU software
No.)

No output available

-

A

A

A

5BH

CPU ID

U1-29

Output power
lower 4 digits

Monitors the MxC’s output
power. The display is split into
upper digits and lower digits in
the following way.

Example: If the output power is
12345678.9 kWh, the display will
be as follows:
U1-29: 678.9 kWH
U1-30: 12345 MWH
(Analog monitor: No output)

0.0 to 32767999.9

0.1

kWH

A

A

A

5CH

kWh Lower 4 dig

U1-30

Output power
upper 5 digits

MW

H

A

A

A

5DH

kWh Upper 5 dig

U1-32

ACR output of q
axis

Monitors the current control out-
put value for the motor secondary
current.

10 V: 100%
(

−10 V to + 10 V possible)

0.1

%

No

A

A

5FH

ACR(q) Output

U1-33

ACR output of d
axis

Monitors the current control out-
put value for the motor excitation
current.

10 V: 100%
(

−10 V to + 10 V possible)

0.1

%

No

A

A

60H

ACR(d) Output

U1-34

OPE fault parame-
ter

Shows the first parameter number
where an OPE fault was detected.

No output available

-

A

A

A

61H

OPE Detected

U1-35

Zero-servo move-
ment pulses

Shows the number of PG pulses
times 4 for the movement range
when stopped at zero.

1

No

No

A

62H

Zero Servo Pulse

U1-36

PID input volume

PID feedback volume
Given as maximum frequency/
100%

10 V: Max frequency
(

−10 V to + 10 V possible)

0.01

%

A

A

A

63H

PID Input

U1-37

PID output volume PID control output

Given as maximum frequency/
100%

10 V: Max frequency
(

−10 V to + 10 V possible)

0.01

%

A

A

A

64H

PID Output

U1-38

PID target value

PID target value
Given as maximum frequency/
100%

10 V: Max frequency

0.01

%

A

A

A

65H

PID Setpoint

U1-39

MEMOBUS
communications
error code

Shows MEMOBUS errors.

No output available

-

A

A

A

66H

Transmit Err

Parameter

Number

Name

Description

Output Signal Level

during Multi-Function

Analog Output

Min.

Unit

Control

Methods

MEMO-

BUS

Register

Display

V/f

Open

Loop

Vector

Flux

Vector

††††† †††††

kWH

U1-30 U1-29

1: CRC error
1: Data length error
Not used (always 0).
1: Parity
error
1: Overrun
error
1: Framing
ޓerror
1: Timeout
Not used (always 0).

U1-39= 00000000