Types and number of cooling fans used in the mxc, How to replace the external cooling fan – Yaskawa Matrix Converter User Manual

Page 351

Advertising
background image

8

-4

‹

Types and Number of Cooling Fans Used in the MxC

Cooling fans used for the MxC has two types; External cooling fan and circulation fan. External cooling fan
blows air to the MxC cooling fin. Circulation fan stirs up the air inside the MxC unit.

Table 8.3 shows the number of cooling fans used in the MxC. Refer to the spare parts list (Manual no.
EZZ020357) for the specifications of cooling fans.

Be sure to use the specified type of fan when replacing the cooling fan. If the wrong fan is used, the MxC may
fail to perform at optimum levels.

‹

How to Replace the External Cooling Fan

„

200 V and 400 V classes, 5.5 kW or 11kW

1. Remove the terminal cover and the front cover.

Table 8.3 Number of Cooling Fans to be Used

Maximum Motor

Capacity

(kW)

200 V class

400 V class

External Cooling Fan

Circulation Fan

External Cooling Fan

Circulation Fan

5.5

2

0

2

0

11

2

0

2

0

22

2

0

2

0

45

2

1

2

1

75

2

1

110

4

2

160

4

2

Mounting screws for front cover

Front cover

Terminal cover

Mounting screws for terminal cover