L7: torque limits – Yaskawa Matrix Converter User Manual

Page 148

Advertising
background image

5

-48

„

L7: Torque Limits

Parameter

Number

Name

Description

Setting

Range

Default

Change

during

Run

Control

Methods

MEMO-

BUS

Register

Page

Display

V/f

Open

Loop

Vector

Flux

Vector

L7-01

Forward Torque
Limit

Sets the torque limit value as a percentage
of the motor rated torque. Four individual
quadrants can be set.

0 to 300 200%

No

No

A

A

4A7H

4-17
6-40

Torq Limit Fwd

L7-02

Reverse Torque
Limit

0 to 300 200%

No

No

A

A

4A8H

4-17
6-40

Torq Limit Rev

L7-03

Forward Regener-
ative Torque
Limit

0 to 300 200%

No

No

A

A

4A9H

4-17
6-40

Torq Lmt Fwd
Rgn

L7-04

Reverse Regener-
ative Torque
Limit

0 to 300 200%

No

No

A

A

4AAH

4-17
6-40

Torq Lmt Rev
Rgn

L7-06

Torque Limit Inte-
gral Time Con-
stant

Sets the torque limit value as a percentage
of the motor rated torque. Four individual
quadrants can be set.

5 to

10,000

200

ms

No

No

A

No

4ACH

4-17
6-40

Torq Limit Time

L7-07

Torque Limit
Control Method
Selection During
Accel/Decel

Selects the method of torque limit con-
trols during accel/decel
0: Proportional Controls (uses integral

controls at fixed speeds).

1: Integral Controls
Adjustment is not normally required.
With applications that require torque lim-
its during accel/decel, integral controls
(setting value = 1) are used when torque
controls take precedence. When torque
limit is applied to the motor, accel/decel
time may increase and motor speed may
not run at the indicated speed reference.

0, 1

0

No

No

A

No

4C9H

4-17
6-40

Torque Limit Sel

Output torque

Positive torque

Reverse

Negative torque

No. of

motor

rotations
Forward

Regenerative

state

Regenerative

state