Test run procedure – Yaskawa Matrix Converter User Manual

Page 85

Advertising
background image

4

-2

Test Run Procedure

Test run the MxC as shown in the flowchart below:

Fig 4.1 Test Run Flowchart

START

Installation

Wiring

Turn on power.

Confirm status.

Basic settings

(Quick Programming Mode)

Select operating
method.

Settings according
to control method

Application settings

(Advanced Programming Mode)

No-load operation

Loaded operation

Optimum adjustments and

Parameter settings

Check/save parameters.

END

YES

V/f

(A1-02 = 0)

Vector (A1-02 = 2 or 3) *2

Set E1-03.
V/f default: 200 V/60 Hz(400 V/60 Hz)

YES

NO

V/f Control?

Motor cable over

50 m or heavy load possibly

causing motor to stall or

overload?

Stationary Auto-Tuning for
line-to-line resistance only

Rotational Auto-Tuning *3

*1

*1 If the motor cable changes to 50 m or longer for the actual
installation, perform stationary Auto-Tuning for the line-to-line
resistance only on-site.

*2 The default control method is Open Loop Vector Control
(A1-02 = 2).

*3 If the maximum output frequency is different from the base
frequency, set the Maximum Output Frequency (E1-04) to the
value of the base frequency after Auto-Tuning.