E3: motor 2 v/f pattern, E4: motor 2 setup – Yaskawa Matrix Converter User Manual

Page 127

Advertising
background image

Parameter Tables

5-

27

„

E3: Motor 2 V/f Pattern

* 1. These are values for a 200 V class MxC. Double the value for a 400 V class MxC.
* 2. The default will change when the control method is changed. The Open Loop Vector defaults are given.

„

E4: Motor 2 Setup

Parameter

Number

Name

Description

Setting

Range

Default

Change

during

Run

Control

Methods

MEMO-

BUS

Register

Page

Display

V/f

Open

Loop

Vector

Flux

Vector

E3-01

Motor 2 Control
Method Selection

0: V/f Control
2: Open Loop Vector Control
3: Flux Vector Control

0, 2, or

3

2

No

A

A

A

319H

-

Control Method

E3-02

Motor 2 Maxi-
mum Output Fre-
quency

To set V/f characteristics in a straight
line, set the same values for E3-05 and
E3-07. In this case, the setting for E3-06
will be disregarded. Be sure that the four
frequencies are set in the following man-
ner or else an OPE10 fault will occur:
E3-02

≥ E3-04 ≥ E3-05 ≥ E3-07

40.0 to

120.0

60.0

Hz

*2

No

A

A

A

31AH

-

Max Frequency

E3-03

Motor 2 Maxi-
mum Output Volt-
age

0.0 to
255.0

*1

200.0

VAC

*1 *2

No

A

A

A

31BH

-

Max Voltage

E3-04

Motor 2 Base Fre-
quency

0.0 to
120.0

60.0

Hz

*2

No

A

A

A

31CH

-

Base Frequency

E3-05

Motor 2 Mid Out-
put Frequency

0.0 to
120.0

3.0 Hz

*2

No

A

A

No

31DH

-

Mid Frequency

E3-06

Motor 2 Mid Out-
put Voltage VA

0.0 to
255.0

*1

13.0

VAC

*1 *2

No

A

A

No

31EH

-

Mid Voltage

E3-07

Motor 2 Mini-
mum Output Fre-
quency

0.0 to
120.0

0.5 Hz

*2

No

A

A

A

31FH

-

Min Frequency

E3-08

Motor 2 Mini-
mum Output Volt-
age

0.0 to
255.0

*1

2.5

VAC

*1 *2

No

A

A

No

320H

-

Min Voltage

Parameter

Number

Name

Description

Setting

Range

Default

Change

during

Run

Control

Methods

MEMO-

BUS

Register

Page

Display

V/f

Open

Loop

Vector

Flux

Vector

E4-01

Motor 2 Rated
Current

Sets the motor 2 name plate full load cur-
rent in amperes (A). This value is auto-
matically set during Auto-Tuning.

2.70

to

54.00

*2

19.60

A

*1

No

A

A

A

321H

6-51

Motor Rated FLA

E4-02

Motor 2 Rated
Slip

Sets the rated slip of motor 2 in hertz
(Hz). This value is automatically set dur-
ing Rotational Auto-Tuning.

0.00 to

20.00

1.50

Hz

*1

No

A

A

A

322H

-

Motor Rated Slip

E4-03

Motor 2 No-Load
Current

Sets the magnetizing current of motor 2
in percentage of full load current (E4-01).
This value is automatically set during
Rotational Auto-Tuning.

0.00 to

19.59

*3

5.10 A

*1

No

A

A

A

323H

-

No-Load Current

Output voltage (V)

Frequency (Hz)

VMAX

VC

VMIN

FMIN

FB

FA

FMAX