6

-18

* The setting range for accel/decel times depends on the setting of C1-10 (Accel/Decel Time Setting Units). If C1-10 is set to 0, the setting range is 0.00 to

600.00 (s).

„

Setting the Units to Express the Acceleration and Deceleration Time

Set the accel/decel time units using C1-10. The default setting for C1-10 is 1.

„

Switching Acceleration and Deceleration Time Using Multi-Function Input Terminal
Commands

The MxC allows for four separate acceleration times and four separate deceleration times. When the multi-
function input terminals (H1-††) are set to 7 (Accel/Decel Time Selection 1) and 1A (Accel/Decel Time
Selection 2), the accel/decel time of the MxC can be changed even while the application is running based on
the terminal switch status.

The following table shows the possible accel/decel time switching combinations.

C2-01

S-Curve Charac-
teristic at Accel
Start

All sections of the S-curve characteristic time
are set in seconds units.
When the S-curve characteristic time is set,
the accel/decel times will increase by only
half of the S-curve characteristic times at start
and end.

0.00 to

2.50

0.20 s

No

A

A

A

SCrv Acc @ Start

C2-02

S-Curve Charac-
teristic at Accel
End

0.00 to

2.50

0.20 s

No

A

A

A

SCrv Acc @ End

C2-03

S-Curve Charac-
teristic at Decel
Start

0.00 to

2.50

0.20 s

No

A

A

A

SCrv Dec @ Start

C2-04

S-Curve Charac-
teristic at Decel
End

0.00 to

2.50

0.00 s

No

A

A

A

SCrv Dec @ End

Set value

Details

0

The accel/decel time settings range is 0.00 to 600.00 in units of 0.01 s.

1

The accel/decel time settings range is 0.0 to 6000.0 in units of 0.1 s.

Accel/Decel Time

Selection 1 Terminal

Accel/Decel Time

Selection 2 Terminal

Acceleration Time

Deceleration Time

off

off

C1-01

C1-02

on

off

C1-03

C1-04

off

on

C1-05

C1-06

on

on

C1-07

C1-08

Parameter

Number

Name

Description

Setting

Range

Default

Change

during

Run

Control Methods

Display

V/f

Open

Loop

Vector

Flux

Vector

Run Command

Output frequency

Time

on

off

C2-02

C2-03

C2-04

C2-01

Advertising