Machine Protection

6-

51

‹

Motor Overload Protection

The MxC’s built-in electronic thermal overload relay protects the motor from overload.

„

Related Parameters

* 1. The default depends on the MxC capacity. The value for a 200 V class MxC of 5.5 kW is given.
* 2. The setting range is from 10% to 200% of the MxC rated output current. The value for a 200 V class MxC for 5.5 kW is given.

Multi-Function Outputs (H2-01 to H2-05)

„

Setting Motor Rated Current

Set the rated current value on the motor nameplate in parameters E2-01 (Motor Rated Current) and E4-01
(Motor 2 Rated Current). This set value is the electronic thermal base current.

Parameter

Number

Name

Description

Setting

Range

Default

Change

during

Run

Control Methods

Display

V/f

Open

Loop

Vector

Flux

Vector

E2-01

Motor Rated Cur-
rent

Sets the motor nameplate full load current in
amperes (A). This value is automatically set
during Auto-Tuning.

2.70 to

54.00

*2

19.60 A

*1

No

Q

Q

Q

Motor Rated FLA

E4-01

Motor 2 Rated
Current

Sets the motor 2 name plate full load current
in amperes (A). This value is automatically
set during Auto-Tuning.

2.70

to

54.00

*2

19.60 A

*1

No

A

A

A

Motor Rated FLA

L1-01

Motor Overload
Protection Selec-
tion

Sets the motor thermal overload protection
(OL1) based on the cooling capacity of the
motor.
0: Disabled.
1: Standard Fan Cooled (< 10:1 motor)
2: Standard Blower Cooled (10:1 motor)
3: Vector Motor (

≤1000:1 motor)

0 to 3

1

No

Q

Q

Q

MOL Fault Select

L1-02

Motor Overload
Protection Time

Sets the motor thermal overload protection
(OL1) time. A larger L1-02 time will increase
the time before an OL1 fault will occur.

0.1 to

5.0

1.0 min

No

A

A

A

MOL Time Const

Set

Value

Function

Control Methods

V/f

Open

Loop

Vector

Flux

Vector

1F

Motor overload (OL1, including OH3) pre-alarm (on: 90% or more of the detection level)

Yes

Yes

Yes

Advertising