Machine Protection
6-
47
Frequency
(FOUT)
Detection
Frequency (FOUT) Detection 5
(L4-01< | output frequency |)
Related
Parameter
L4-01: Speed Agree Level
L4-02: Speed Agree Width
L4-03: Speed Agree Level +/
−
L4-04: Speed Agree Width +/
−
Output
frequency
or motor
speed
Frequency
(FOUT) detection 5
(Multi-function output setting = 36)
off during base block
off
on
L4-02
L4-02
L4-01
L4-01