V/f Pattern

The diagrams show characteristics for a 200 V class motor. For a 400 V class motor, multiply all voltages by
2.

Constant Torque Characteristics (Set Value: 0 to 3)

Decrement Torque Characteristics (Set Value: 4 to 7)

High Startup Torque (Set Value: 8 to B)

Fixed Output Operation (Set Value: C to E)

Set Value 0

50 Hz

Set Value 1

60 Hz

Set Value 2

60 Hz

Set Value 3

72 Hz

(Initial value of set value F)

Set Value 4

50 Hz

Set Value 5

50 Hz

Set Value 6

60 Hz

Set Value 7

60 Hz

Set Value 8

50 Hz

Set Value 9

50 Hz

Set Value A

60 Hz

Set Value B

60 Hz

Set Value C

90 Hz

Set Value D

120 Hz