Yaskawa Matrix Converter User Manual

Page 122

Advertising
background image

5

-22

„

d3: Jump Frequencies

„

d4: Reference Frequency Hold

Parameter

Number

Name

Description

Setting

Range

Default

Change

during

Run

Control

Methods

MEMO-

BUS

Register

Page

Display

V/f

Open

Loop

Vector

Flux

Vector

d3-01

Jump Frequency 1 Set the center values of the jump frequen-

cies in Hz.
This function is disabled by setting the
jump frequency to 0 Hz. Always ensure
that the following applies:
d3-01

≥ d3-02 ≥ d3-03

Operation in the jump frequency range is
prohibited but during acceleration and
deceleration, speed changes smoothly
without jump.

0.0 to
120.0

0.0 Hz

No

A

A

A

294H

4-17
6-28

Jump Freq 1

d3-02

Jump Frequency 2

0.0 Hz

No

A

A

A

295H

4-17
6-28

Jump Freq 2

d3-03

Jump Frequency 3

0.0 Hz

No

A

A

A

296H

4-17
6-28

Jump Freq 3

d3-04

Jump Frequency
Width

Sets the jump frequency bandwidth in
Hz.
The jump frequency will be the jump fre-
quency

± d3-04.

0.0 to

20.0

1.0 Hz

No

A

A

A

297H

4-17
6-28

Jump Bandwidth

Parameter

Number

Name

Description

Setting

Range

Default

Change

during

Run

Control

Methods

MEMO-

BUS

Register

Page

Display

V/f

Open

Loop

Vector

Flux

Vector

d4-01

Frequency Refer-
ence Hold Func-
tion Selection

Sets whether or not frequencies on hold
will be recorded.
0: Disabled (when operation is stopped

or the power is turned on again starts
at 0.)

1: Enabled (when operation is stopped

or the power is turned on again starts
at the previous hold frequency.)

This function is available when the multi-
function inputs “accel/decel Ramp Hold”
or “up/down” commands are set.

0 or 1

0

No

A

A

A

298H

6-69

MOP Ref Mem-
ory

d4-02

Trim Control
Level

Set the frequency to be added to or sub-
tracted from the analog frequency refer-
ence as a percent, taking the maximum
output frequency to be 100%.
Enabled when the increase (+) speed
command or decrease (-) speed command
is set for a multi-function input.

0 to 100

10%

No

A

A

A

299H

6-73

Trim Control Lvl

Advertising