5

-52

‹

o: Digital Operator

The following settings are made with the digital operator parameters (o parameters): Selection of items dis-
played on the digital operator, multi-function selections and the copy function.

„

o1: Monitor Select

* The digital operator shows rpm instead of min

-1

.

Parameter

Number

Name

Description

Setting

Range

Default

Change

during

Run

Control

Methods

MEMO-

BUS

Register

Page

Display

V/f

Open

Loop

Vector

Flux

Vector

o1-01

User Monitor
Selection

Set the number of the monitor item to be
displayed (U1-††).
Items that can be set differ in accordance
with the selected control modes.
The output monitor voltage (default) can
be changed.
For information on the parameters for
which analog output is possible, refer to
U: Monitors.

4 to 99

6

Yes

A

A

A

500H

-

User Monitor Sel

o1-02

User Monitor
Selection After
Power-Up

Sets the monitor item to be displayed
when the power is turned on.
1: Frequency reference
2: Output frequency
3: Output current
4: The monitor item set for o1-01

1 to 4

1

Yes

A

A

A

501H

6-125

Power-On Moni-
tor

o1-03

Digital Operator
Display Selection

Sets the units that will be set and dis-
played for the frequency reference and
frequency monitor.
0: 0.01 Hz units
1: 0.01% units (Maximum output fre-

quency is 100%)

2 to 39:

min

−1 ∗

units (Sets the motor poles.)

40 to 39999:

User desired display
Set the desired values for setting and
display for the max. output frequency.

Example: When the max. output fre-
quency value is 200.0, set 12000.

0 to

39999

0

No

A

A

A

502H

6-125
6-142

Display Scaling

o1-04

Setting unit for
frequency param-
eters related to V/
f characteristics

Set the setting unit for frequency refer-
ence-related parameters.
0: Hz
1: min

−1 ∗

0 or 1

0

No

No

No

A

503H

6-125

Display Units

o1-05

LCD Brightness
Adjustment

Adjust the brightness of the LCD.
Set a smaller value to lighten the LCD
and a larger value to darken the LCD
(standard: 3).

0 to 5

3

No

A

A

A

504H

-

LCD Contrast

غغغغغ

غغغغغ

Set 4-digit number
excluding the decimal
point.

Set the number of digits
below the decimal point
to display.

Advertising