Yaskawa Matrix Converter User Manual

Page 136

Advertising
background image

5

-36

18

Timer function input (Functions are set in b4-01 and b4-02 and the timer function
outputs are set in H1-†† and H2-††).

Yes

Yes

Yes

6-93

19

PID control disable (ON: PID control disabled)

Yes

Yes

Yes

6-97

1A

Accel/Decel time 2

Yes

Yes

Yes

6-18

1B

Parameters write enable (ON: All parameters can be written-in. off: All parameters
other than frequency monitor are write protected).

Yes

Yes

Yes

6-133

7-18

1C

Trim control increase (ON: d4-02 frequency is added to analog frequency reference). Yes

Yes

Yes

6-73

1D

Trim control decrease (ON: d4-02 frequency is subtracted from analog frequency ref-
erence).

Yes

Yes

Yes

6-73

1E

Analog frequency reference sample/hold

Yes

Yes

Yes

6-74

20 to 2F

External fault (Desired settings possible)
Input Mode: NO contact/NC contact, Detection Mode: Normal/during run

Yes

Yes

Yes

6-76

30

PID control integral reset (reset when Reset Command is input or when stopped dur-
ing PID control)

Yes

Yes

Yes

6-97

31

PID control integral hold (ON: Hold)

Yes

Yes

Yes

6-97

32

Multi-step speed reference 4

Yes

Yes

Yes

-

34

PID soft starter

Yes

Yes

Yes

6-97

35

PID input characteristics switch

Yes

Yes

Yes

6-97

60

DC Injection Braking Command (ON: Performs DC injection braking)

Yes

Yes

Yes

6-15

61

External Search Command 1 (ON: Speed search from maximum output frequency)

Yes

Yes

No

6-60

62

External Search Command 2 (ON: Speed search from set frequency)

Yes

Yes

No

6-60

63

Field Weakening Command (ON: Field weakening control set for d6-01 and d6-02)

Yes

No

No

-

64

External Speed Search Command 3

Yes

Yes

Yes

-

67

Communications Test Mode (“Pass” is displayed when the communications test is
passed).

Yes

Yes

Yes

6-93

71

Speed/torque control change (ON: Torque control)

No

No

Yes

6-109
6-114

72

Zero-Servo Command (ON: Zero-servo)

No

No

Yes

6-123

77

Speed control (ASR) proportional gain switch (ON: C5-03)

No

No

Yes

6-116

78

Polarity Reversing Command for external torque reference

No

No

Yes

6-109

Set

Value

Function

Control

Methods

Page

V/f

Open

Loop

Vector

Flux

Vector

Advertising