Selecting the number of pg (encoder) pulses – Yaskawa Matrix Converter User Manual

Page 67

Advertising
background image

Installing and Wiring Option Cards

2-

33

‹

Selecting the Number of PG (Encoder) Pulses

The setting for the number of PG pulses depends on the model of PG Speed Control Card being used. Set the
correct number for your model.

„

PG-B2

The maximum response frequency is 32,767 Hz.

Use a PG that outputs a maximum frequency of approximately 20 kHz for the rotational speed of the motor.

Some examples of PG output frequency (number of pulses) for the maximum frequency output are shown in
Table 2.16.

Note: 1. The motor speed at maximum frequency output is expressed as the sync rotation speed.

2. The PG power supply is 12 V.
3. A separate power supply is required if the PG power supply capacity is greater than 200 mA (If momentary power loss must be handled, use a

backup capacitor or other method).

Fig 2.28 PG-B2 Connection Example

Table 2.16 PG Pulse Selection Examples

Motor's Maximum Speed

(min

−1

)

PG Rating

(p/rev)

PG Output Frequency for Maximum

Frequency Output (Hz)

1800

600

18,000

1500

600

15,000

1200

900

18,000

900

1200

18,000

Motor speed at maximum frequency output (min

−1

)

60

× PG rating (p/rev) = 20,000 Hz

TA1

TA3

0 V 12 V

PG

PG

0 V

+12 V

+

+

+

-

-

0 V

+

+

-

-

1
2

3
4
5
6

PG power supply

Capacitor for momentary
power loss

Signals