Yaskawa Matrix Converter User Manual

Page 275

Advertising
background image

6

-110

Monitor Function

„

Inputting Torque References and Torque Reference Directions

The torque reference can be changed according to an analog input by setting H3-09 (Terminal A2 Function
Selection) or H3-05 (Terminal A3 Function Selection) to 13 (torque reference) or 14 (torque compensation).
The torque reference input methods are listed in the following table.

The direction of the torque output from the motor will be determined by the sign of the analog signal input. It
does not depend on the direction of the Run Command. The direction of torque will be as follows:

Positive analog reference: Torque reference for forward motor rotation (counterclockwise as viewed from
the motor output axis).

Negative analog reference: Torque reference for reverse motor rotation (clockwise as viewed from the
motor output axis).

Parameter

Number

Name

Description

Output Signal Level

During Multi-Function

Analog Output

Min.

Unit

Control Methods

Display

V/f

Open

Loop

Vector

Flux

Vector

U1-09

Torque reference

Monitors internal torque reference
value for vector control.

10 V: Motor rated torque
(-10 V to +10 V possible)

0.1

%

No

A

A

Torque Reference

Torque Reference Input

Method

Reference Location

Selection

Method

Remarks

Voltage input (0 to

±

10 V)

Between A3 and AC

H3-04 = 1
H3-05 = 13

Set H3-04 to 0 for a 0 to 10 V torque ref-
erence.
To switch the torque reference between
positive and negative torque, set a multi-
function analog input to 78.

Between A2 and AC
(Turn off pin 2 of
SW1.)

H3-08 = 1
H3-09 = 13

Set H3-08 to 0 for a 0 to 10 V torque ref-
erence.
To switch the torque reference between
positive and negative torque, set a multi-
function analog input to 78.
The input can be used for torque compen-
sation by setting H3-09 to 14.

Current input (4 to 20 mA)

Between A2 and AC
(Turn on pin 2 of
SW1.)

H3-08 = 2
H3-09 = 13

To switch the torque reference between
positive and negative torque, set a multi-
function analog input to 78.
The input can be used for torque compen-
sation by setting H3-09 to 14.

Option card (AI-14B)
(0 to

±

10 V)

Between TC2 and TC4

F2-01 = 0
H3-08 = 1
H3-09 = 13

The input can be used for torque compen-
sation by setting H3-05 to 14.

Advertising