Yaskawa Matrix Converter User Manual

Page 304

Advertising
background image

Options

6-

139

„

Related Parameters

„

Setting Output Items for the DO-02C Digital Output Card

If using DO-02C Digital Output Card, set the output items using F5-01 and F5-02.

Parameter

Number

Name

Description

Setting

Range

Default

Change

during

Run

Control Methods

Display

V/f

Open

Loop

Vector

Flux

Vector

F5-01

DO-02/DO-08
Channel 1 Output
Selection

Sets the digital output function number for
channel 1. See the H2 parameter group for
possible selections.
Enabled when digital output card DO-02 or
DO-08 is used.

0 to 37

0

No

A

A

A

DO Ch1 Select

F5-02

DO-02/DO-08
Channel 2 Output
Selection

Sets the digital output function number for
channel 2. See the H2 parameter group for
possible selections.
Enabled when digital output card DO-02 or
DO-08 is used.

0 to 37

1

No

A

A

A

DO Ch2 Select

F5-03

DO-08 Channel 3
Output Selection

Sets the digital output function number for
channel 3. See the H2 parameter group for
possible selections.
Enabled when digital output card DO-02 or
DO-08 is used.

0 to 37

2

No

A

A

A

DO Ch3 Select

F5-04

DO-08 Channel 4
Output Selection

Sets the digital output function number for
channel 4. See the H2 parameter group for
possible selections.
Enabled when digital output card DO-02 or
DO-08 is used.

0 to 37

4

No

A

A

A

DO Ch4 Select

F5-05

DO-08 Channel 5
Output Selection

Sets the digital output function number for
channel 5. See the H2 parameter group for
possible selections.
Enabled when digital output card DO-02 or
DO-08 is used.

0 to 37

6

No

A

A

A

DO Ch5 Select

F5-06

DO-08 Channel 6
Output Selection

Sets the digital output function number for
channel 6. See the H2 parameter group for
possible selections.
Enabled when digital output card DO-02 or
DO-08 is used.

0 to 37

37

No

A

A

A

DO Ch6 Select

F5-07

DO-08 Channel 7
Output Selection

Sets the digital output function number for
channel 7. See the H2 parameter group for
possible selections.
Enabled when digital output card DO-02 or
DO-08 is used.

0 to 37

0F

No

A

A

A

DO Ch7 Select

F5-08

DO-08 Channel 8
Output Selection

Sets the digital output function number for
channel 8. See the H2 parameter group for
possible selections.
Enabled when digital output card DO-02 or
DO-08 is used.

0 to 37

0F

No

A

A

A

DO Ch8 Select

F5-09

DO-08 Output
Mode Selection

Sets the function of the DO-08 digital output
option card.
0: 8-channel individual outputs.
1: Binary code output.
2: 8-channel Selected - Output according to

F5-01 to F5-08 settings.

0 to 2

0

No

A

A

A

DO-08 Selection

Advertising