6

-46

Timing Chart for Frequency Detection Operation

Related

Parameter

L4-01: Speed Agree Level

L4-02: Speed Agree Width

L4-03: Speed Agree Level +/

L4-04: Speed Agree Width +/

Fref/Fout
Agree

Fref/Fout Agree 1

Fref/Fout Agree 2

Fref/Set
Agree

Fref/Set Agree 1
Switches on under the following conditions during
Frequency Agree.

Fref/Set Agree 2
Switches on under the following conditions during
Frequency Agree.

Frequency
Detection

Frequency (FOUT) Detection 1
(L4-01

> | output frequency |)

Frequency (FOUT) Detection 3
(L4-03

> output frequency)

Frequency (FOUT) Detection 2
(L4-01

< | output frequency |)

Frequency (FOUT) Detection 4
(L4-01

< output frequency)

L4-02

off

on

Frequency

reference

L4-02

Output frequency

or motor speed

Fref/Fout Agree 1

(Multi-function output setting = 2)

off

on

Frequency

reference

Output frequency

or motor speed

Fref/Fout Agree 2

L4-04

(Multi-function output setting = 13)

off

on

Output frequency

or motor speed

Fref/Set Agree 1

L4-02

L4-01

L4-01

L4-02

(Multi-function output setting = 3)

off

on

Output frequency

or motor speed

Fref/Set Agree 2

L4-04

L4-03

(Multi-function output setting = 14)

Freq. Detection 1

off

on

Output frequency

or motor speed

L4-02

L4-02

L4-01

L4-01

(Multi-function output setting = 4)

Freq. Detection 3

off

on

Output frequency

or motor speed

L4-04

L4-03

(Multi-function output setting = 15)

Freq. Detection 2

off

on

Output frequency

or motor speed

L4-02

L4-02

L4-01

L4-01

(Multi-function output setting = 5)

Freq. Detection 4

off

on

Output frequency

or motor speed

L4-04

L4-03

(Multi-function output setting = 16)