Defaults for various mxc capacities (o2-04) – Yaskawa Matrix Converter User Manual

Page 165

Advertising
background image

Parameter Tables

5-

65

* 1. These are setting range and default value for a 200 V class MxC. Values for a 400 V class MxC are double.
* 2. Settings vary as shown in the following tables depending on the MxC capacity and E1-03.

„

200 V and 400 V Class MxCs of 5.5 to 75 kW

* The setting shown are for 200 V class MxCs. The values will double for 400 V class MxCs.

‹

Defaults for Various MxC Capacities (o2-04)

If the MxC capacity (o2-04) is changed, the defaults of the following parameters will change.

F1-09

Overspeed Detection Delay Time

0.0 to 2.0

0.1 s

-

-

0.0

PG Overspd Time

Parameter

Number

Unit

Default

Open

Loop

Vector

Control

Flux

Vector

Control

E1-03

-

0

1

2

3

4

5

6

7

8

9

A

B

C

D

F

E1-04

Hz

50.0

60.0

60.0

72.0

50.0

50.0

60.0

60.0

50.0

50.0

60.0

60.0

90.0

120.0

60.0

60.0

60.0

E1-05 *

V

200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0

200.0

200.0

E1-06

Hz

50.0

60.0

50.0

60.0

50.0

50.0

60.0

60.0

50.0

50.0

60.0

60.0

60.0

60.0

60.0

60.0

0.0

E1-07

Hz

2.5

3.0

3.0

3.0

25.0

25.0

30.0

30.0

2.5

2.5

3.0

3.0

3.0

3.0

3.0

3.0

0.0

E1-08 *

V

14.0

14.0

14.0

14.0

35.0

50.0

35.0

50.0

18.0

23.0

18.0

23.0

14.0

14.0

14.0

13.0

0.0

E1-09

Hz

1.3

1.5

1.5

1.5

1.3

1.3

1.5

1.5

1.3

1.3

1.5

1.5

1.5

1.5

1.5

0.5

0.0

E1-10 *

V

7.0

7.0

7.0

7.0

6.0

7.0

6.0

7.0

9.0

11.0

9.0

13.0

7.0

7.0

7.0

2.5

0.0

Parameter

Number

Name

Unit

Default

200 V class

400 V class

-

MxC Capacity

kW

5.5

11

22

45

5.5

11

22

45

75

110 160

E2-11

Motor Rated Output

E4-07

Motor 2 Rated Output

o2-04

MxC/kVA Selection

-

5

7

A

D

26

28

2B

2E

30

32

34

E2-01

(E4-01)

Motor Rated Current

A

19.60 39.7

77.2 160.0 9.80

19.9

38.6

79.7 130.0 190.0 270.0

E2-02

(E4-02)

Motor Rated Slip

Hz

1.50

1.70

1.70

1.60

1.50

1.70

1.70

1.60

1.39

1.40

1.35

E2-03

(E4-03)

Motor No-Load Current

A

5.10

11.2

18.5

44.0

2.60

5.6

9.2

22.0

36.0

49.0

70.0

E2-05

(E4-05)

Motor Line-to-Line Resis-
tance

Ω

0.399 0.230 0.079 0.030 1.595 0.922 0.316 0.122 0.092 0.046 0.029

E2-06

(E4-06)

Motor Leakage Inductance

%

18.2

19.5

19.5

20.2

18.2

19.6

23.5

19.9

20.0

20.0

20.0

E2-10

Motor Iron Loss for Torque
Compensation

W

172

245

538

852

193

385

586

1125 1600 2150 2850

n5-02

Motor Acceleration Time

s

0.168 0.265 0.355 0.387 0.168 0.265 0.355 0.387 0.533 0.646 0.777

L8-02

Overheat Alarm Level

°C

90

90

85

90

85

85

85

90

90

1.7

1.9

L2-03

Momentary Power Loss
Minimum Base Block Time

s

0.7

0.9

1.1

0.7

0.7

0.9

1.1

1.2

1.5

115

115

Parameter

Number

Name

Setting Range

Unit

Default

Display

V/f

Control

Open loop

Vector

Flux

Vector