Test Run Procedures

4-

11

„

Parameter Settings for Auto-Tuning

The following parameters must be set before Auto-Tuning.

* 1. Not normally displayed. Displayed only when a Motor Switch Command is set for a multi-function digital input (one of H1-01 to H1-06 set to 16).
* 2. The default will change when the control method is changed. The V/f Control Method default is given.
* 3. For a constant-output motor, set the value at the base speed.
* 4. For an inverter motor or vector motor, the voltage and frequency may be lower than for a general-purpose motor. Always confirm setting on the name-

plate or in test reports. Also, if you know the no-load values, set the no-load voltage in T1-03 and the no-load frequency in T1-05 to obtain better accu-

racy.

* 5. Stable vector control will be possible when the setting is between 75% and 100% of MxC rating.
* 6. The digital operator shows rpm instead of min

-1

.

Table 4.2 Parameter Settings before Auto-Tuning

Parameter

Number

Name

Display

Setting

Range

Default

Data Displays during

Auto-Tuning

V/f

Open

Loop

Vector

Flux

Vector

T1-00

Motor 1/2
Selection

*1

Selects which set of motor parameters are
to be used and set during Auto-Tuning. If
Motor 2 selection (H1-††=16) is not
selected, this parameter will not be dis-
played.
1: 1st Motor - E1 to E2
2: 2nd Motor - E3 to E4

1 or 2

1

Yes

Yes

Yes

T1-01

Auto-Tun-

ing Mode

Selection

Selects the Auto-Tuning Mode.
0: Rotational Auto-Tuning (A1-02 = 2 or

3)

2: Terminal resistance only, (stationary)

Auto-Tuning (A1-02 = 0, 1, 2, or 3)

4: Stationary Auto-Tuning 2

0 to 2, 4

*8

0

*2

Yes

(only

for 2)

Yes

Yes

T1-02

Motor Out-

put Power

Sets the motor rated power in kilowatts
(kW).

*3 *5

0.00 to

650.00 kW

5.50 kW

*6

Yes

Yes

Yes

T1-03

Motor Rated

Voltage

Sets the motor rated voltage in Volts (V).

*3

*4

0.0 to 255.0 V

(200 V class)

0.0 to 510.0 V

(400 V class)

200.0 V

(200 V class)

400.0 V

(400 V class)

-

Yes

Yes

T1-04

Motor Rated

Current

Sets the motor rated current in Amperes
(A).

*3 *5

2.70 to 54.00

A

*9

19.60 A

*6

Yes

Yes

Yes

T1-05

Motor Base

Frequency

Sets the base frequency of the motor in
Hertz (Hz).

*3 *4

0.0 to 120.0

60.0 Hz

-

Yes

Yes

T1-06

Number of

Motor Poles Sets the number of motor poles.

2 to 48 poles

*10

4 poles

-

Yes

Yes

T1-07

Motor Base

Speed

Sets the base speed of the motor in
min

-1 *3 *6

0 to 24000

1750 min

-1

-

Yes

Yes

T1-08

Number of

PG Pulses

when Turn-

ing

Sets the number of pulses per revolution
(PPR) for the encoder (pulse generator)
being used without any multiplication fac-
tor.

0 to 60000

600

-

-

Yes

T1-09

Motor No-

Load Cur-

rent

Set the motor no-load current to the value
indicated shown in the motor test report or
other specification sheets.
This parameter is displayed only when Sta-
tionary Auto-Tuning 2 (T1-01 = 4) is
selected.

0.00 to 19.59

*7

5.10 A

*6

No

No

Yes

T1-10

Motor Rated

Slip

Set the amount of the motor rated slip in
hertz.
This parameter is displayed only if Station-
ary Auto-Tuning 2 (T1-01 = 4) is selected.

0.00 to 20.00

1.50 Hz

*6

-

Yes

Yes

Advertising