Speed control (asr) structure – Yaskawa Matrix Converter User Manual

Page 280

Advertising
background image

Individual Functions

6-

115

When A1-02 (Control Method Selection) is set to 3 (Flux Vector Control), the Speed/Torque Change Com-
mand (a setting of 71) can be set for a multi-function input (H1-01 to H1-10) to switch between speed and
torque control during run. An example is shown below.

A timing chart for switching between speed and torque control is shown in the following figure.

Fig 6.69 Speed/Torque Control Switching Time Chart.

‹

Speed Control (ASR) Structure

Speed control (ASR) during vector control adjusts the torque reference so that the deviation between the speed
reference and the estimated speed (PG feedback or speed estimator) is 0. The following block diagram shows
the structure of the speed control for vector control.

Fig 6.70 Speed Control Block Diagrams

Terminal No.

Parameter No.

Default

Setting

Function

8

H1-06

8

71

Speed/torque control change

A1

b1-01

1

1

Frequency reference selection
(terminals A1, A2)

C5-03

1

1

Speed limit (terminals A1, A2)

A3

H3-05

0

13

Torque reference/torque limit

Speed/torque change signal
(terminal S8 input)

Run Command

Control mode

Terminal A1 input

Terminal A3 input

Stop

OPEN

CLOSED

OPEN

CLOSED

Run

Speed

Torque

Speed

Torque

Speed (decel to stop)

Speed
reference

Speed limit

Speed
reference

Speed limit

Torque limit

Torque
reference

Torque limit

Torque
reference

Frequency
reference

Detected speed

Estimated speed

P

I

Torque limits

Torque reference

+

+

+

Speed Control Block Diagram for Vector Control

C5-01, C5-03

C5-02, C5-04

C5-06

I

limit

C5-08

Primary
filter

L7-01 to L7-04

(C5-10)

Advertising