Verify mode, Using the verify mode, Operation modes – Yaskawa Matrix Converter User Manual

Page 81: Fig 3.8 operations in verify mode

Advertising
background image

Operation Modes

3-

13

‹

Verify Mode

The Verify Mode displays any parameters that have been changed from their default settings. This includes all
parameters that were changed by the user in the Programming Mode, and all parameters that were changed
when Auto-Tuning was performed. If no parameter settings have been changed, then the Verify Mode display
window will read, “None”.

The Verify Mode will not show parameters belonging to the A1: Initialization Settings group (i.e., all parame-
ters that start with A1-

††

), even if those parameters have been changed. The exception is A1-02, which will

appear if it has been changed from its default value.

The user can also change parameter settings while in the Verify Mode. Just as in the Programming Mode, use
the up arrow, down arrow, and SHIFT/RESET keys to adjust any setting values. Save changes by pressing the
DATA/ENTER key.

„

Using the Verify Mode

The example below demonstrates how to use the Verify Mode to view parameters that have been set to values
different from their default settings. In the example, the following parameters have been changed: b1-01 (Ref-
erence Selection), C1-01 (Acceleration Time 1), E1-01 (Input Voltage Setting), and E2-01 (Motor Rated Cur-
rent).

Fig 3.8 Operations in Verify Mode

** Main Menu **

-DRIVE-

Operation

** Main Menu **

-QUICK-

Quick Setting

** Main Menu **

-ADV-

Programming

** Main Menu **

-VERIFY-

Modified Consts

** Main Menu **

-A.TUNE-

Auto-Tuning

MENU

MENU

MENU

MENU

MENU

Monitor display

Setting display

Mode selection display

DATA

ENTER

Reference Source

-VERIFY-

b1-01=0

*0*

Terminals

ESC

DATA

ENTER

Accel Time 1

-VERIFY-

(0.0

㨪6000.0)

̍10.0Sec̍

C1-01=200.0Sec

A

B

A

B

Reference Source

-VERIFY-

b1-01=

0

*0*

Terminals

DATA

ENTER

ESC

DATA

ENTER

ESC

DATA

ENTER

ESC

Input Voltage

-VERIFY-

(155

㨪255)

̍200VAC̍

E1-01=200VAC

Motor Rated FLA

-VERIFY-

(0.32

㨪6.40)

̍1.90A̍

E2-01=2.00A

Motor Rated FLA

-VERIFY-

(0.32

㨪6.40)

̍1.90A̍

E2-01=

2

.00A

Input Voltage

-VERIFY-

(155

㨪255)

̍200V̍

E1-01=

2

00VAC

Accel Time 1

-VERIFY-

(0.0

㨪6000.0)

̍10.0Sec̍

C1-01=

0

200.0Sec

DATA

ENTER

ESC

"1"

"1"

Advertising