5-

33

„

F6: Communications Option Cards

F5-09

DO-08 Output
Mode Selection

Sets the function of the DO-08 digital
output option card.
0: 8-channel individual outputs.
1: Binary code output.
2: 8-channel Selected - Output accord-

ing to F5-01 to F5-08 settings.

0 to 2

0

No

A

A

A

3A1H

6-139

DO-08 Selection

Parameter

Number

Name

Description

Setting

Range

Default

Change

during

Run

Control

Methods

MEMO-

BUS

Register

Page

Display

V/f

Open

Loop

Vector

Flux

Vector

F6-01

Operation Selec-
tion after Com-
munication Error

Selects the stopping method for a com-
munication option card fault (BUS).
Active only when a communication
option card is installed and b1-01 or b1-
02 = 3.
0: Decelerate to Stop
1: Coast to Stop
2: Fast-Stop
3: Alarm Only

0 to 3

1

No

A

A

A

3A2H

-

Comm Bus Flt Sel

F6-02

Selection of
External Fault
from Communi-
cation Option
Card

Selects the condition in which an EF0
fault is detected from a communication
option card. Active only when a commu-
nication option card is installed and b1-01
or b1-02 = 3.
0: Always detected.
1: Detected only during run.

0 or 1

0

No

A

A

A

3A3H

-

EF0 Detection

F6-03

Stopping Method
for External Fault
from Communi-
cation Option
Card

Selects the stopping method for an exter-
nal fault from a communication option
card (EF0). Active only when a commu-
nication option card is installed and b1-01
or b1-02 = 3.
0: Decelerate to Stop
1: Coast to Stop
2: Fast-Stop
3: Alarm Only

0 to 3

1

No

A

A

A

3A4H

-

EF0 Fault Action

F6-04

Trace Sampling
from Communi-
cations Option
Card

0 to

60000

0

No

A

A

A

3A5H

-

Trace Sample Tim

F6-06

Torque Reference/
Torque Limit
Selection from
Communications
Option

Selects torque reference/limit when using
communications option card.
0: Disabled. - Torque reference/limit

from option card disabled

1: Enabled.- Torque reference/limit from

option card enabled.

0 or 1

0

No

No

No

A

3A7H

-

Torq Ref/Lmt Sel

Parameter

Number

Name

Description

Setting

Range

Default

Change

during

Run

Control

Methods

MEMO-

BUS

Register

Page

Display

V/f

Open

Loop

Vector

Flux

Vector