Related parameters – Yaskawa Matrix Converter User Manual

Page 285

Advertising
background image

6

-120

‹

Increasing the Speed Reference Response (Feed Forward Control)

Use feed forward control to increase the responsiveness to speed references. This function is enabled for
machines for which the ASR gain cannot be increased to a large value because doing so would result in oscil-
lations. There is also the additional effect of making the system less prone to overshoot. This function is valid
only in Flux Vector Control.

Fig 6.75 Overshoot Suppression

„

Related Parameters

* The default depends on the MxC capacity. The value for a 200 V class MxC of 5.5 kW is given.

Parameter

Number

Name

Description

Setting

Range

Default

Change

during

Run

Control Methods

Display

V/f

Open

Loop

Vector

Flux

Vector

n5-01

Feed Forward
Control Selection

Selects the feed forward controls.
0: Disabled.
1: Enabled.

0 or 1

0

No

No

No

A

Feedfoward Sel

n5-02

Motor Accelera-
tion Time

Sets the time required to accelerate the motor
at the rated torque (T100) to the rated speed
(Nr).
J: (GD

2

) / 4, P: Motor rated output

And

0.001 to

10.000

0.168 s

*

No

No

No

A

Motor Accel Time

n5-03

Feed Forward
Control Ratio Gain

Sets the proportional gain for feed forward
controls.
Response to the speed reference will increase
as the setting of n5-03 is increased.

0.00 to
100.00

1.0

No

No

No

A

Feedfoward Gain

Overshoot

The overshoot is suppressed
at completion of acceleration.

Motor
speed

Motor
speed

Time (s)

Time (s)

Feed-forward control

Conventional speed control

2

π J[kgm

2

] Nr[min

-1

]

[sec]

ta =

60 T

100

[N

m]

T

100

=

60



× 10

3

[N m]

2

π

P[kW]

Nr[min

-1

]

Advertising