5

-50

‹

n: Special Adjustments

The following settings are made with the special adjustments parameters (N parameters): Hunting prevention,
speed feedback detection control, and feed forward control.

„

n1: Hunting Prevention Function

Parameter

Number

Name

Description

Setting

Range

Default

Change

during

Run

Control

Methods

MEMO-

BUS

Register

Page

Display

V/f

Open

Loop

Vector

Flux

Vector

n1-01

Hunting Preven-
tion Selection

0: Hunting-prevention function disabled
1: Hunting-prevention function enabled
The hunting-prevention function sup-
presses hunting when the motor is operat-
ing with a light load.
This function is enabled in V/f Control
method only.
If high response is to be given priority
over vibration suppression, disable the
hunting-prevention function.

0 or 1

1

No

A

No

No

580H

6-36

Hunt Prev Select

n1-02

Hunting Preven-
tion Gain Setting

Set the hunting-prevention gain multipli-
cation factor.
Normally, there is no need to make this
setting.
Adjust this parameter as follows:
• If vibration occurs with light load,

increase the setting.

• If the motor stalls, reduce the setting.
If the setting is too large, the voltage will
be too suppressed and the motor may
stall.

0.00 to

2.50

1.00

No

A

No

No

581H

4-14
6-36

Hunt Prev Gain

n1-03

Hunting Preven-
tion Time Con-
stant

Set the hunting-prevention primary delay
time in units of ms.

0 to 500 10 ms

No

A

No

No

582H

6-36

Hunt Prev Time