Yaskawa Matrix Converter User Manual

Page 274

Advertising
background image

Individual Functions

6-

109

Multi-Function Digital Input Functions (H1-01 to H1-10)

Multi-Function Digital Output Functions (H2-01 to H2-05)

Multi-Function Analog Inputs (H3-05, H3-09)

H3-06

Terminal A3 Gain
Setting

Sets the output level when 10 V is input.

0.0 to

1000.0

100.0%

Yes

A

A

A

Terminal A3 Gain

H3-07

Terminal A3 Bias
Setting

Sets the frequency reference when 0 V is
input.

-100.0

to

+100.0

0.0%

Yes

A

A

A

Terminal A3 Bias

H3-08

Terminal A2 Sig-
nal Level Selection

Selects the signal level of terminal A2.
0: 0 to 10 VDC (switch S1-2 must be in the

off position).

1: -10 to +10 VDC (switch S1-2 must be in

the off position).

2: 4 to 20 mA (switch S1-2 must be in the on

position)

Note: Switch between current or voltage

inputs by using (S1-2) switch on the

terminal board.

0 to 2

2

No

A

A

A

Term A2 Signal

H3-09

Terminal A2 Func-
tion Selection

Select multi-function analog input function
for terminal A2. Refer to the next table.

0 to 1F

0

No

A

A

A

Terminal A2 Sel

H3-10

Terminal A2 Gain
Setting

Sets the output level when 10V is input.

0.0 to

1000.0

100.0%

Yes

A

A

A

Terminal A2 Gain

H3-11

Terminal A2 Bias
Setting

Sets the output level when 0V is input.

-100.0

to

+100.0

0.0%

Yes

A

A

A

Terminal A2 Bias

Set

Value

Function

Control Methods

V/f

Open

Loop

Vector

Flux

Vector

71

Speed/torque control change (closed: torque control)

No

No

Yes

78

Polarity Reverse Command for external torque reference

No

No

Yes

Set

Value

Function

Control Methods

V/f

Open

Loop

Vector

Flux

Vector

32

Speed control circuit operating for torque control (except when stopped).
The external torque reference will be limited if torque control is selected.
Output when the motor is rotating at the speed limit.

No

No

Yes

Set

Value

Function

Control Methods

V/f

Open

Loop

Vector

Flux

Vector

0

Add to terminal A1

Yes

Yes

Yes

13

Torque reference/torque limit at speed control

No

No

Yes

14

Torque compensation

No

No

Yes

Parameter

Number

Name

Description

Setting

Range

Default

Change

during

Run

Control Methods

Display

V/f

Open

Loop

Vector

Flux

Vector

Advertising