Improved Operating Efficiency

6-

37

‹

Stabilizing Speed (Speed Feedback Detection Function)

The speed feedback detection control (AFR) function measures the stability of the speed when a load is sud-
denly applied by calculating the amount of fluctuation of the torque current feedback value, and compensating
the output frequency with the amount of fluctuation.

„

Related Parameters

Parameter

Number

Name

Description

Setting

Range

Default

Change

during

Run

Control Methods

Display

V/f

Open

Loop

Vector

Flux

Vector

n2-01

Speed Feedback
Detection Control
(AFR) Gain

Set the internal speed feedback detection con-
trol gain using the multiplication function.
Normally, there is no need to make this set-
ting.
Adjust this parameter as follows:
• If hunting occurs, increase the set value.
• If response is low, decrease the set value.
Adjust the setting by 0.05 at a time, while
checking the response.

0.00 to

10.00

1.00

No

No

A

No

AFR Gain

n2-02

Speed Feedback
Detection Control
(AFR) Time Con-
stant

Set the time constant to decide the rate of
change in the speed feedback detection con-
trol.

0 to

2000

100 ms

No

No

A

No

AFR Time

n2-03

Speed Feedback
Detection Control
(AFR) Time Con-
stant 2

Increase the setting if overvoltage (OV) fail-
ures occur at the completion of acceleration or
when the load changes radically.

0 to

2000

750 ms

No

No

A

No

AFR Time 2