L5: fault restart „ l6: torque detection – Yaskawa Matrix Converter User Manual

Page 147

Advertising
background image

Parameter Tables

5-

47

„

L5: Fault Restart

„

L6: Torque Detection

The following table shows the parameters for the torque detection function.

Parameter

Number

Name

Description

Setting

Range

Default

Change

during

Run

Control

Methods

MEMO-

BUS

Register

Page

Display

V/f

Open

Loop

Vector

Flux

Vector

L5-01

Number of Auto
Restart Attempts

Sets the number of auto restart attempts.
Automatically restarts after a fault and
conducts a speed search from the run fre-
quency.

0 to 10

0

No

A

A

A

49EH

6-65

Num of Restarts

L5-02

Auto Restart
Operation Selec-
tion

Sets whether a fault contact output is acti-
vated during fault restart.
0: Not output (Fault contact is not acti-

vated.)

1: Output (Fault contact is activated.)

0 or 1

0

No

A

A

A

49FH

6-65

Restart Sel

Parameter

Number

Name

Description

Setting

Range

Default

Change

during

Run

Control

Methods

MEMO-

BUS

Register

Page

Display

V/f

Open

Loop

Vector

Flux

Vector

L6-01

Torque Detection
Selection 1

0: Overtorque/undertorque detection disabled.
1: Overtorque detection only with speed

agreement; operation continues after over-
torque (warning).

2: Overtorque detected continuously during

operation; operation continues after over-
torque (warning).

3: Overtorque detection only with speed

agreement; output stopped upon detection
(protected operation).

4: Overtorque detected continuously during

operation; output stopped upon detection
(protected operation).

5: Undertorque detection only with speed

agreement; operation continues after over-
torque (warning).

6: Undertorque detected continuously during

operation; operation continues after over-
torque (warning).

7: Undertorque detection only with speed

agreement; output stopped upon detection
(protected operation).

8: Undertorque detected continuously during

operation; output stopped upon detection
(protected operation).

0 to 8

0

No

A

A

A

4A1H

6-48

Torq Det 1 Sel

L6-02

Torque Detection
Level 1

Open Loop Vector Control: Motor rated torque
is set as 100%.
V/f Control: MxC rated current is set as 100%.

0 to
300

150%

No

A

A

A

4A2H

6-48

Torq Det 1 Lvl

L6-03

Torque Detection
Time 1

Sets the overtorque/undertorque detection time
in 1-second units.

0.0 to

10.0

0.1 s

No

A

A

A

4A3H

6-48

Torq Det 1 Time

L6-04

Torque Detection
Selection 2

Multi-function output for overtorque detection
1 is output to multi-function contact output
when overtorque detection 1 NO or overtorque
detection 1 NC is selected.
Multi-function output for overtorque detection
2 is output to multi-function contact output
when overtorque detection 2 NO or overtorque
detection 2 NC is selected.

0 to 8

0

No

A

A

A

4A4H

6-48

Torq Det 2 Sel

L6-05

Torque Detection
Level 2

0 to
300

150%

No

A

A

A

4A5H

6-48

Torq Det 2 Lvl

L6-06

Torque Detection
Time 2

0.0 to

10.0

0.1 s

No

A

A

A

4A6H

6-48

Torq Det 2 Time