Connection Example and Time Chart

The following diagram and time chart show how to set up the control circuit terminal for a 9-step speed
sequence.

Fig 6.5 Control Circuit Terminal during 9-Step Operation

Fig 6.6 Multi-Step Speed Reference/Jog Frequency Selection Time Chart

Setting Precautions

When setting analog inputs to step 1 to step 2, observe the following precautions.

Step 1
When setting terminal A1’s analog input to step 2, set b1-01 to 1, and when setting d1-01 (Frequency Ref-
erence 1) to step 1, set b1-01 to 0.

Step 2
When setting the analog input for terminal A2 to step 2, also set H3-09 to 2 (Auxiliary Frequency Refer-
ence 1). When setting d1-02 (Frequency Reference 2) to step 2, set H3-05 to 1F (do not use analog inputs).

Step 3
When setting terminal A3’s analog input to step 3, set H3-05 to 3 (Auxiliary Frequency Reference 2).
When setting d1-03 (Frequency Reference 3) to step 3, set H3-05 to 1F (analog input not used).

MxC

S1 Forward/stop

S2 Reverse/stop

S3 External fault

S4 Fault reset

S5 Multi-step speed reference 1

S6 Multi-step speed reference 2

S9 Multi-step speed reference 3

SC Sequence common

S7 Jog frequency

Forward/stop

Multi-Step Speed
Reference 1

Multi-Step Speed
Reference 2
Multi-Step Speed
Reference 3
Jog Frequency
Selection

Frequency

Reference 3

Frequency

Reference 4

Frequency

Reference 5

Frequency

Reference 6

Jog Frequency

Frequency

Reference 8

Frequency

Reference 7

Frequency

Reference

Frequency Reference 1:

Master Speed

Frequency

Frequency Reference 2:

Auxiliary Speed Frequency

on