Stopping Methods

6-

15

‹

Using DC Injection Braking

Set parameter b2-03 to apply DC Injection Braking current to the motor while it is coasting to stop. This
allows the MxC to stop the motor more quickly than simply allowing it to coast, and also to restart the motor
again.

Set b2-03 to 0 to disable DC Injection Braking at start.

Set the DC injection braking current using b2-02. DC injection braking is used at start up in Flux Vector Con-
trol with the current set in E2-03 (Motor No-Load Current).

„

Related Parameters

„

Inputting DC Injection Braking Command from Control Circuit Terminals

If a multi-function digital input terminal (H1-††) is set to 60 (DC Injection Braking Command), DC Injec-
tion Braking can be applied to the motor is applied by enabling the terminal for which DC Injection Braking
Command has been set when the MxC is being stopped. DC Injection Braking is used at startup in Flux Vector
Control.

The time chart for DC Injection Braking is shown below.

Fig 6.17 DC Injection Brake Time Chart

Parameter

Number

Name

Description

Setting

Range

Default

Change

during

Run

Control Methods

Display

V/f

Open

Loop

Vector

Flux

Vector

b2-02

DC Injection Brak-
ing Current

Sets the DC Injection Braking current as a
percentage of the MxC rated current.
Note: The DC excitation current is deter-

mined by the setting in E2-03 when

operating in Flux Loop Vector Control

Method.

0 to
100

50%

No

A

A

No

DCInj Current

b2-03

DC Injection Brak-
ing Time/DC Exci-
tation Time at Start Sets the time of DC Injection Braking at start

in units of 0.01 seconds.

0.00

to

10.00

0.00 s

No

A

A

A

DCInj Time
@Start

DC injection brake

(DC injection braking at

startup is used for flux

vector control.)

E1-09

b2-01

DC Injection Braking Command

FRUN

Output frequency

DC injection brake

(DC injection braking at

startup is used for flux

vector control.)

If you input DC Injection Braking Command from an external terminal, or if the Run Command

and Jog Command are input, DC Injection Brake will be disabled, and operation will resume.