-140

„

Setting Output Items for the DO-08 Digital Output Card

If using DO-08 Digital Output Card, select one of the following three output modes according to the setting in
F5-09.

F5-09 Set to 0

F5-09 Set to 1

The following table shows the code outputs.

F5-09 Set to 2

Output depends on the settings in F5-01 to F5-08.

Set Value

Terminal

Number

Output Details

0: 8 separate

outputs

TD5-TD11

Overcurrent (OC, GF)

TD6-TD11

Overvoltage (OV, AOV)

TD7-TD11

MxC overload (OL2, OH2)

TD8-TD11

Not used

TD9-TD11

Overspeed (OS)

TD10-TD11

MxC overheated (OH1) or motor overload (OL1)

TD1-TD2

Zero-speed detected

TD3-TD4

Speed Agree

Set Value

Terminal

Number

Output Details

1: Binary code

output

TD5-TD11

bit 0

Encoded output
(Refer to table below)

TD6-TD11

bit 1

TD7-TD11

bit 2

TD8-TD11

bit 3

TD9-TD11

Zero-speed detected

TD10-TD11

Speed Agree

TD1-TD2

Operating

TD3-TD4

Minor fault

Bits 3, 2, 1,

and 0

Output Details

Bits 3, 2, 1,

and 0

Output Details

0000

No error

1000

External fault (EF

††

)

0001

Overcurrent (OC, GF)

1001

Controller error (CPF

††

)

0010

Overvoltage (OV, AOV)

1010

Motor overload (OL1)

0011

MxC overload (OL2, OH2)

1011

Not used

0100

MxC overheated (OH, OH1)

1100

Power loss (UV1, UV2, FDV, AUV, or SRC)

0101

Overspeed (OS)

1101

Speed deviation (DEV)

0110

Not used

1110

PG Disconnect (PGO)

0111

Built-in resistor overheated (SOH, DOH)

1111

Not used