C00905

C00909

C00910

Parameter | Name:

C00905 | Motor phase direction of rotation

Data type: UNSIGNED_8

Index: 23670

d

= 5C76

h

From version 04.00.00

To correct such misconnected motor phases, the rotating field of the controller's output can be reversed by selecting

"1: Inverted". In this case, a phase will be reversed at the output of the inverter.

Note:

Up to and including version 11.00.00

, this function may only be activated for the following motor control types:

• V/f characteristic control (VFCplus)

• Energy-saving V/f characteristic control (VFCplusEco)

For all other motor control types, this function must not be activated because the set control mode would not work

in that case!

From version 12.00.00

, this function may be activated for all motor control types with the exception of the ones for

synchronous motor.

The activation of this function does not affect the control types for synchronous motor since these control types

require an in-phase connection of the synchronous motor.
Selection list

(Lenze setting printed in bold)

0 not inverted
1 inverted

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00909 | Speed limitation

Data type: INTEGER_16

Index: 23666

d

= 5C72

h

Max. positive/negative speed for all motor control modes
Setting range

(min. value | unit | max. value)

0.00

%

175.00

Subcodes

Lenze setting

Info

C00909/1

120.00 %

Max. pos. speed

C00909/2

120.00 %

Max. neg. speed

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00910 | Frequency limitation

Data type: UNSIGNED_16

Index: 23665

d

= 5C71

h

Max. positive/negative output frequency for all motor control modes
Setting range

(min. value | unit | max. value)

0

Hz

1300

Subcodes

Lenze setting

Info

C00910/1

1000 Hz

Max. pos. output frequency

C00910/2

1000 Hz

Max. neg. output frequency

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1