8basic drive functions (mck) – Lenze 8400 HighLine User Manual

Page 534

Advertising
background image

8

Basic drive functions (MCK)

8.4

Basic settings

534

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.4.4

Target position monitoring (status "drive in target")

The target position monitoring detects whether the drive has reached the target.

Short overview of the parameters for target position monitoring:

Principal procedure of the position detection

[8-18] Signal characteristics

Note!

• The target position detection is active with the following operating modes/functions:

• Operating mode "

Positioning

": Absolute and relative positioning mode

• Operating mode "

Homing

": After approaching the starting position via start profile

(if start profile has been selected)

• Operating mode "

Manual jog

": When the breakpoints and the software limit

positions are approached

• The target position monitoring is active until the operating mode changes or a new

travel command influences the setpoint.

Parameter

Info

Lenze setting

Value Unit

C01244/1

MCK: Dwell time - target position

• For considering mechanical transient phenomenons of

the tool when the target position is reached.

100 ms

C01245/1

MCK: Window target position

• Symmetrical window around the target position.

1.0000 units

target position window (symmetrically around the target position; 2 x C01245/1)

dwell time

dnTargetPosition_p

bDone

TRUE

FALSE

bDwellTime

TRUE

FALSE

bInTarget

TRUE

FALSE

dnSetPosition_p

dnActPosition_p

t

t

t

t

C01244/1

C01245/1



Œ

C01245/1

0

1

2

Advertising