C02312 | ls_writeparamlist: pli without motion, C02312/1, C02312/2 – Lenze 8400 HighLine User Manual

Page 1126: C02312/3, C02312/4, C02313/1, C02313/2, C02313/3, C02313/4, 15 parameter reference

Advertising
background image

15

Parameter reference

15.2

Parameter list | C02312

1126

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02312

C02313

Parameter | Name:

C02312 | LS_WriteParamList: PLI without motion

Data type: UNSIGNED_16

Index: 22263

d

= 56F7

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. hex value | max. hex value)

0x0000

0xFFFF

Value is bit-coded:

Bit 0 for SLPSM with controller enable
Bit 1 for SC PSM with mains on
Bit 2 for SC PSM with controller enable
Bit 3 for SC PSM once after fault reset
Bit 4

Reserved

Bit 5

Reserved

Bit 6

Reserved

Bit 7

Reserved

Bit 8

Reserved

Bit 9

Reserved

Bit 10

Reserved

Bit 11

Reserved

Bit 12

Reserved

Bit 13

Reserved

Bit 14

Reserved

Bit 15

Reserved

Subcodes

Lenze setting

Info

C02312/1

0x0001

LS_WriteParamList

: c2874_s1_val1

C02312/2

0x0001

LS_WriteParamList

: c2874_s1_val2

C02312/3

0x0001

LS_WriteParamList

: c2874_s1_val3

C02312/4

0x0001

LS_WriteParamList

: c2874_s1_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Parameter | Name:

C02313 | LS_WriteParamList: PLI without motion: Adaptation of ident angle

Data type: INTEGER_8

Index: 22262

d

= 56F6

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

-100

°

100

Subcodes

Lenze setting

Info

C02313/1

0 °

LS_WriteParamList

: c2875_s1_val1

C02313/2

0 °

LS_WriteParamList

: c2875_s1_val2

C02313/3

0 °

LS_WriteParamList

: c2875_s1_val3

C02313/4

0 °

LS_WriteParamList

: c2875_s1_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT