163 l_srfg_2, 163 l_srfg_2 2, L_srfg_2 – Lenze 8400 HighLine User Manual

Page 1502: 17 function library

Advertising
background image

17

Function library

17.1

Function blocks

1502

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

17.1.163

L_SRFG_2

This FB is a ramp function generator with S-shaped ramps for limiting the temporal rise of analog

signals. The ramps are S-shaped due to trapezoidal acceleration.

• The ramp function generator is provided with a setting function so that a value can directly be

loaded into the internal ramp generator.

• The balanced acceleration/deceleration time is set in

C01040

.

• An S-ramp time can be set in

C01041

for jerk-free acceleration until maximum acceleration is

reached.

• At the nDeltaOut_a output, the dy/dt slope of the nOut_a output signal is output.

Inputs

Outputs

Parameter

Identifier

Data type

Information/possible settings

nIn_a

INT

Input signal

nSet_a

INT

Starting value for the ramp function generator

• Will be accepted if bLoad = TRUE

bLoad

BOOL

Initialise ramp function generator

FALSE With the set acceleration/deceleration time, the ramp function

generator switches over from the value loaded via nSet_a to the

value at nIn_a.

TRUE At the nOut_a output, nSet_a is output.

nDeltaOut_a remains at 0 %.

Identifier

Data type

Value/meaning

nDeltaOut_a

INT

Acceleration of the ramp function generator

• Internal limitation to ±100 % (100 % ≡ 16384)

nOut_a

INT

Output signal

• Internal limitation to ±199 % (100 % ≡ 16384)

Parameter

Possible settings

Info

C01040/2

0.001

s

999.999 Acceleration/Deceleration time

• Initialisation: 100.000 s

C01041/2

0.001

s

50.000 S-ramp time

• Initialisation: 0.200 s

/B65)*B

Q2XWBD

Q,QBD

Q6HWBD

E/RDG

Q'HOWD2XWBD





& $FFHOGHFHOWLPH

&

3RVOLPLW

& -HUNWLPH

&
1HJOLPLW







Advertising