C01075 | l_dfset_1: synchronisation mode, C01076 | l_dfrfg_1: times, C01077 | l_dfrfg_1: max. speed-up – Lenze 8400 HighLine User Manual

Page 1049: 15 parameter reference

Advertising
background image

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

1049

15

Parameter reference

15.2

Parameter list | C01075

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01075

C01076

C01077

Parameter | Name:

C01075 | L_DFSET_1: Synchronisation mode

Data type: UNSIGNED_8

Index: 23500

d

= 5BCC

h

From version 11.00.00

Selection list

0 Inactive
1 Permanent sync. without enable

(bZeroPulse)

2 Permanent sync. with enable

(bZeroPulse)

10 1x sync. - Angular diff. shortest path

setpoint

11 1x Sync. - Angular diff. Cw
12 1x Sync. - Angular diff. Ccw
13 1x Sync. - Angular diff. shortest path

act. value

Subcodes

Lenze setting

Info

C01075/1

0: Inactive

L_DFSET_1

: Synchronisation mode

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01076 | L_DFRFG_1: Times

Data type: UNSIGNED_32

Index: 23499

d

= 5BCB

h

From version 11.00.00

Setting range

(min. value | unit | max. value)

0.000

s

999.900

Subcodes

Lenze setting

Info

C01076/1

1.000 s

L_DFRFG_1

: Acceleration and deceleration time

C01076/2

0.000 s

L_DFRFG_1

: Deceleration time for quick stop

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000

Parameter | Name:

C01077 | L_DFRFG_1: Max. speed-up

Data type: INTEGER_16

Index: 23498

d

= 5BCA

h

From version 11.00.00

Setting range

(min. value | unit | max. value)

1

rpm

15000

Subcodes

Lenze setting

Info

C01077/1

3000 rpm

L_DFRFG_1

: Max. speed-up

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1