Basic drive functions (MCK)

8.12

Holding brake control

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

[8-41] Close holding brake in automatic mode with actual value monitoring time (

C02593/1

> 0 s)

Feedforward control

C02581/1

: Switching threshold

C02581/2

: Hysteresis for release

C02581/3

: Hysteresis for application

C02593/2

: Application delay

C02593/1

: Actual value monitoring time

C02589/1

: Application time

Œ 

bMBrakeReleaseOut

0

0

bMBrakeReleased

CINH

t

t

t

t

nSpeedSetValue_a_



‘





0

nMotorSpeedAct_a

nSpeedSetValue_a

Œ

Œ Ž