17 function library – Lenze 8400 HighLine User Manual

Page 1501

Advertising
background image

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

1501

17

Function library

17.1

Function blocks

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Loading the ramp function generator
When bLoad is set to TRUE, the ramp function generator is loaded with the signal at nSet_a. This

value is accepted immediately and output at nOut_a. There is no acceleration or deceleration via an

S shape. As long as bLoad = TRUE, the ramp function generator remains inhibited.

Acceleration/Deceleration time and S-ramp time
The acceleration/deceleration time and the S-ramp time for jerk-free acceleration can be set

separately.

• Acceleration/Deceleration time = Time until the nOut_a output value has reached the nIn_a

input value.

• S-ramp time = Time until the ramp function generator operates at maximum acceleration.

[17-70] Signal flow

C01042/1

(from version 05.00.00)

-199.99

s

199.99 Pos. limit

• Initialisation: 100.00 %

C01042/2

(from version 05.00.00)

-199.99

s

199.99 Neg. limit

• Initialisation: -100.00 %

C01040/x

: Acceleration/Deceleration time

C01041/x

: S-ramp time

Parameter

Possible settings

Info

nIn_a

t

nOut_a

t

nDeltaOut_a

t

Œ









Œ

+100 %

-100 %

Advertising