C00161 | ls_seterror_x: error number, C00162 | error number masked, C00163 | logbook - binary elements – Lenze 8400 HighLine User Manual

Page 839: C00163/1, C00163/2, C00162/1, Additiona, Detected by reading the, Code, C161/1

Advertising
background image

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

839

15

Parameter reference

15.2

Parameter list | C00161

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00161

C00162

C00163

Parameter | Name:

C00161 | LS_SetError_x: Error number

Data type: UNSIGNED_16

Index: 24414

d

= 5F5E

h

Setting of the error number for user error messages
Setting range

(min. value | unit | max. value)

0

65535

Subcodes

Lenze setting

Info

C00161/1

1

LS_SetError_1

: Error no.1

C00161/2

2

LS_SetError_1

: Error no.2

C00161/3

3

LS_SetError_1

: Error no.3

C00161/4

4

LS_SetError_1

: Error no.4

C00161/5

1

LS_SetError_2

: Error no.1

C00161/6

2

LS_SetError_2

: Error no.2

C00161/7

3

LS_SetError_2

: Error no.3

C00161/8

4

LS_SetError_2

: Error no.4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00162 | Error number masked

Data type: UNSIGNED_32

Index: 24413

d

= 5F5D

h

From version 13.00.00

Display of the 32-bit error number of the status determining error without error type

• The error number displayed here only contains the error subject area and error ID (lower 26 bits of the 32-bit error

number)

Structure of the 32-bit error number (bit coding)

Display range

(min. value | unit | max. value)

0

4294967295

Subcodes

Info

C00162/1

Subject area + Id statuserror

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00163 | Logbook - binary elements

Data type: UNSIGNED_16

Index: 24412

d

= 5F5C

h

Selection of two binary signals to be logged in the logbook
Selection list

Info

0 No signal
1 DI1: Input signal
2 DI2: Input signal
3 DI3: Input signal
4 DI4: Input signal
5 Controller inhibit signal
6 Digital counter: Comparison bit
7 CAN1 input bit 0
8 CAN1 input bit 1
9 CAN1 input bit 2

10 CAN1 input bit 3

Advertising