5 speed follower, 1 parameter setting, 1 functional settings – Lenze 8400 HighLine User Manual

Page 544: Speed follower, Parameter setting, Functional settings, Reques, 8basic drive functions (mck)

Advertising
background image

8

Basic drive functions (MCK)

8.5

Speed follower

544

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.5

Speed follower

In the "speed follower" operating mode, the drive follows a speed setpoint.

8.5.1

Parameter setting

Short overview of parameters for the "speed follower" operating mode:

8.5.1.1

Functional settings

In

C01219

, various functional settings for the speed follower can be made in bit-coded form.

Parameter

Info

Lenze setting

Value Unit

C01219

MCK: Speed follower setting

Bit coded

C02610/2

MCK: Ramp time synchr. setpoint

2.000 s

C02611/1

MCK: Pos. max. speed

199.99 %

C02611/2

MCK: Pos. min. speed

0.00 %

C02611/3

MCK: Neg. min. speed

0.00 %

C02611/4

MCK: Neg. max. speed

199.99 %

Function

Lenze setting

Bit 0 Reserved

Off

Bit 1 Reserved

Off

Bit 2 HW limit switch on

In the "speed follower" operating mode, a travel range monitoring mode via

hardware limit switch is active.

Limit position monitoring ( 530)

On

Bit 3 SW limit switch on

In the "speed follower" operating mode, a travel range monitoring mode via

parameterised software limit positions.

Limit position monitoring ( 530)

On

Bit 4 Reserved

Off

Bit 5 Reserved

Off

Bit 6 Reserved

Off

Bit 7 Position controller off

In the "Speed follower" operating mode, the position controller is

deactivated. Thus, the compensation of the following error is switched off.

Off

Advertising