Note!

Exchange of devices
When devices with a parameterised servo control for asynchronous motors are

exchanged, problems regarding the control quality may occur if motor parameters set

for a device lower than version 11.00.00 are transferred to a replacement device of a

higher version.

• In this case, we recommend to load the very precise motor data available from

»Engineer« V2.17 or to execute the "advanced motor parameter identification"

(

C02867/1

= 2).

Automatic motor data identification

( 138)

• As an alternative, the slip calculation from the motor nameplate data can be set again

in

C02879/1

(bit 1 = "0") to obtain the previous behaviour.