26 ls_parfreeunit, 26 ls_parfreeunit 9, Ls_parfreeunit – Lenze 8400 HighLine User Manual

Page 1539: 17 function library

Advertising
background image

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

1539

17

Function library

17.2

System blocks

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

17.2.26

LS_ParFreeUnit

This system block outputs 16 parameterisable position signals.

• In contrast to the SB

LS_ParFree_p

, the positions are set in the application unit [unit] instead of

in [increments].

• The bDataValid status signal indicates that the internal position conversion is completed and

the output data are consistent.

Outputs

Parameter

Identifier

Data type

Value/meaning

bDataValid

BOOL

Status signal "Position conversion completed, data consistent"

TRUE The conversion of the positions from [unit] to [increments] is

completed.

dnC475_1 ... dnC475_16

DINT

Output of the position signals parameterised in

C00475/1...16

in [increments]

• Observe bDataValid status signal!

Parameter

Possible settings

Info

C00475/1...16

-214748.3647

unit

214748.3647 Setting of the position signals to be

output

GQ&B

GQ&B

GQ&B

GQ&B

GQ&B

&

&

&

&

&

/6B3DU)UHH8QLW

E'DWD9DOLG

Advertising