6 monitoring, Monitoring, E monitoring – Lenze 8400 HighLine User Manual

Page 631: 9diagnostics & error management

Advertising
background image

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

631

9

Diagnostics & error management

9.6

Monitoring

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

9.6

Monitoring

The controller is provided with various monitoring functions which protect the drive against

impermissible operating conditions.

• If a monitoring function responds,

• an entry will be made into the

Logbook

of the controller,

• the response (TroubleQSP, Warning, Fault, etc.) set for this monitoring function will be

triggered,

• the status of the internal device control changes according to the selected response,

controller inhibit is set, and the "DRV- ERR" LED on the front of the controller goes on:

Related topics:

LED status displays of the device status

( 617)

Device state machine and device states

( 111)

Device overload monitoring (Ixt)

( 295)

Motor load monitoring (I2xt)

( 296)

Motor temperature monitoring (PTC)

( 299)

Brake resistor monitoring (I2xt)

( 300)

Motor phase failure monitoring

( 302)

Mains phase failure monitoring

( 305)

Maximum current monitoring

( 305)

Maximum torque monitoring

( 306)

Encoder open-circuit monitoring

( 307)

Response

Entry in the

logbook

Display in

C00168

Disable

voltage

Controller

inhibit

Acknowledge

ment

required

"DRV-ERR" LED

None

OFF

Fault

Trouble

TroubleQSP

WarningLocked

Warning

Information

OFF

System fault

Mains

switching

is required!

Advertising