21 l_arithmetikphi_3, 21 l_arithmetikphi_3 7, L_arithmetikphi_3 – Lenze 8400 HighLine User Manual

Page 1257: 17 function library

Advertising
background image

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

1257

17

Function library

17.1

Function blocks

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

17.1.21

L_ArithmetikPhi_3

This FB can combine two angle signals arithmetically.

• The arithmetic function is selected in

C01010/3

.

• All internal intermediate results and the value provided at the dnOut_p output are internally

limited to ±2147483647 (±2

31

- 1).

• Division is not remainder considered.

Inputs

Outputs

Parameter

Identifier

Data type

Information/possible settings

dnIn1_p

DINT

Input signal 1

dnIn2_p

DINT

Input signal 2

Identifier

Data type

Value/meaning

dnOut_p

DINT

Output signal

• Internal limitation to ±2147483647

Parameter

Possible settings

Info

C01010/3

Function selection

0 dnOut_p = dnIn1_p
1 dnOut_p = dnIn1_p + dnIn2_p
2 dnOut_p = dnIn1_p - dnIn2_p
3 dnOut_p = dnIn1_p * dnIn2_p
4 dnOut_p = dnIn1_p / dnIn2_p

/B$ULWKPHWLN3KLB

GQ,QBS

GQ2XWBS

GQ,QBS

r

& )XQFWLRQ

Advertising