Parameter reference

15.2

Parameter list | C00088

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00088

C00089

C00090

C00091

C00092

Parameter | Name:

C00088 | Rated motor current

Data type: UNSIGNED_16

Index: 24487

d

= 5FA7

h

This value can be obtained from the motor nameplate. After the motor to be used has been selected from the motor

catalogue, the suitable value can be entered automatically.
Setting range

(min. value | unit | max. value)

Lenze setting

0.20

A

320.00 21.00 A

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00089 | Rated motor frequency

Data type: UNSIGNED_16

Index: 24486

d

= 5FA6

h

This value can be obtained from the motor nameplate. After the motor to be used has been selected from the motor

catalogue, the suitable value can be entered automatically.

Note:

It is mandatory to give the rated motor frequency for the sensorless vector control (

SLVC

) and the servo control (

SC

).

Setting range

(min. value | unit | max. value)

Lenze setting

1

Hz

1000 50 Hz

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00090 | Rated motor voltage

Data type: UNSIGNED_16

Index: 24485

d

= 5FA5

h

This value can be obtained from the motor nameplate. After the motor to be used has been selected from the motor

catalogue, the suitable value can be entered automatically.
Setting range

(min. value | unit | max. value)

Lenze setting

0

V

5000 400 V

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00091 | Motor cosine phi

Data type: UNSIGNED_8

Index: 24484

d

= 5FA4

h

This value can be obtained from the motor nameplate. After the motor to be used has been selected from the motor

catalogue, the suitable value can be entered automatically.
Setting range

(min. value | unit | max. value)

Lenze setting

0.40

1.00 0.85

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00092 | Motor magnetising inductance

Data type: UNSIGNED_16

Index: 24483

d

= 5FA3

h

After the motor to be used has been selected from the motor catalogue, the suitable value can be entered

automatically. An automatic detection via the motor parameter identification is possible as well.
Setting range

(min. value | unit | max. value)

Lenze setting

0.0

mH

6500.0 81.0 mH

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10

Advertising