17 function library – Lenze 8400 HighLine User Manual

Page 1324

Advertising
background image

17

Function library

17.1

Function blocks

1324

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Selecting the characteristic
The max. 32 interpolation points of the characteristic are selected via the subcodes of

C00963

and

C00964

.

• The values are to be set as raw values (±16384 ≡ ±100 %).
• The same subcodes of

C00963

and

C00964

correspond to one pair of variates/interpolation

point (x

n

, y

n

).

• The first pair of variates (

C00963/1

and

C00964/1

) is always valid.

• The X values of the characteristic must be entered in ascending order (X1 < X2 < … < X32).
• An interruption of the ascending order of the X values represents the end of the characteristic

(in our example: X5 < X4):

• Starting at the last valid pairs of variates, extrapolation is performed on both sides until the end

of the X value range (±199.99 %).

Special cases

• Step changes/discontinuities can be displayed by using the same parameter setting for two

consecutive X values. A step change is only valid if it has a valid pair of variates. Otherwise,

extrapolation continues, starting at the last valid pair of variates.

[17-23] Example: Characteristic with step change

1

2

...

32

X

C00963/1

C00963/2

C00963/...

C00963/32

Y

C00964/1

C00964/2

C00964/...

C00964/32

1

2

3

4

5

6

7

...

32

X

-22938

(-140 %)

-14746

(-90 %)

11469

(70 %)

23757

(145 %)

0

0

0

0

0

Y

-22938

(-140 %)

-6554

(-40 %)

18842

(115 %)

26215

(160 %)

0

0

0

0

0

1

2

3

4

5

6

7

...

32

X

-21300

(-130 %)

-11469

(-70 %)

-11469

(-70 %)

13107

(80 %)

0

0

0

0

0

Y

-24576

(-150 %)

-12288

(-75 %)

13927

(85 %)

26215

(160 %)

0

0

0

0

0

nOut_a

nIn_a

X1, Y1

X3, Y3

X4, Y4

-199.99 % / -199.99 %

199.99 % / 199.99 %

X2, Y2

Advertising