C00595

Parameter | Name:

C00595 | MCK: Resp. to MCK error

Data type: UNSIGNED_8

Index: 23980

d

= 5DAC

h

Configuration of monitoring of the Motion Control Kernel

Basic drive functions

Selection list

0 No Reaction
1 Fault
3 TroubleQuickStop
4 WarningLocked
5 Warning
6 Information

Subcodes

Lenze setting

Info

C00595/1

3: TroubleQuickStop

Response if the input bLimitSwitchPos for travel range

monitoring is set to FALSE (fail-safe) by the positive

hardware limit switch .

C00595/2

3: TroubleQuickStop

Response if the input bLimitSwitchNeg for travel range

monitoring is set to FALSE (fail-safe) by the negative

hardware limit switch .

C00595/3

3: TroubleQuickStop

Response for detection that the position is beyond the

positive software limit position (

C01229/1

).

C00595/4

3: TroubleQuickStop

Response for detection that the position is beyond the

negative software limit position (

C01229/2

).

C00595/5

5: Warning

Response if following error limit 1 is exceeded

(

C01215/1

)

C00595/6

5: Warning

Response if following error limit 2 is exceeded

(

C01215/2

)

C00595/7

3: TroubleQuickStop

Response if the maximum travel distance (display in

C01213/1

) is exceeded

C00595/8

4: WarningLocked

Response to start procedures with reference condition

when the reference is not set

C00595/9

4: WarningLocked

Response to a non-supported positioning mode

C00595/10

4: WarningLocked

Response to implausible profile set data

C00595/11

5: Warning

Response to the selection of an invalid operating mode

of the MCK

C00595/12

4: WarningLocked

Response to indicating an invalid profile data set

C00595/13

5: Warning

Response to an error of the FB

L_MckCtrlInterface_1

C00595/14

4: WarningLocked

Response to a profile start with a target position outside

the software limit positions (

C01229/1

and

C01229/2

).

C00595/15

1: Fault

Response to activated connection monitoring in case of

PC manual control

From version 06.00.00

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT