Advertising
background image

8

Basic drive functions (MCK)

8.6

Homing

564

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.6.3

Execute homing

Control is exercised by means of bits 8 ... 10 in the

MCK control word

:

If the Motion Control Kernel is downstream from the MCKInterface in the circuit, the

L_MckCtrlInterface

FB provides the following process inputs for controlling the operating mode:

Homing

MCK control word

Bit 10

Bit 9

Bit 8

HomResetPos

HomSetPos

HomStartStop

Stop homing

0

0

0

Start homing

0

0

1

Set home position

0

1

X

Delete home position

1

0

X

X = Status not significant

Identifier

Data type

Information/possible settings

bHomingStartStop

BOOL

Start/stop homing

• Only possible in the "referencing" operating mode.

TRUE If one of homing modes "4" ... "15" in

C01221

is selected:

Start reference search

• The current status of the reference search is indicated via the

status outputs bHomingDone and bHomePosAvailable.

If homing mode "100: SetRef" is selected in

C01221

:

Setting the home position manually

• The home position is set manually with the drive at a standstill.

The current actual position now corresponds to the reference

position set in

C01227/2

in the machine measuring system.

TRUEFALSE Stop homing.

• If the bHomingStartStop input is reset to FALSE during active

referencing, homing is cancelled and the drive is brought to a

standstill.

bHomingSetPos

BOOL

Set home position (

Homing on the fly

)

• With referencing "on the fly", the home position of a machine can be set during

ongoing movement. Jerking and compensating movements do not occur.

FALSETRUE The position applied at the dnMotorRefOffset_p input of the

SB

LS_MotionControlKernel

at the time of activation is set as home

position if

C01246/2

= "0: No TP" is set.

bHomingResetPos

BOOL

Delete home position

Note: With this function, positions are not deleted but only the status signals

bHomePosAvailable and bHomePosDone are reset. Setpoints and actual positions

remain untouched until a renewed reference setting or homing.

FALSETRUE The internal status "reference known" is reset.

• The controller is no longer referenced.

• The process outputs bHomePosAvailable and bHomingDone are

reset to FALSE.