1about this documentation – Lenze 8400 HighLine User Manual

Page 24

Advertising
background image

1

About this documentation

1.3

Terminology used

24

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Function block

General designation of a function block for free interconnection in the FB Editor.

A function block (short: FB) can be compared with an integrated circuit that contains a

specific control logic and delivers one or several values when being executed. Example:

"L_Arithmetik_1" (FB for arithmetic operations)

Many function block are available several times (e.g. L_And_1, L_And_2 and L_And_3).

Function blocks

Holding brake

The holding brake serves to statically hold e.g. a position during the downtimes of a

robot/travelling/synchronous/hoist drive.
INTERBUS was developed as sensor/actuator/bus system for transmitting process data.

Today, maintenance activities for the INTERBUS technologies are carried out by the user

organisation PROFIBUS & PROFINET International (PI).

Keypad

The keypad is an alternative to the PC for the local operation, parameterisation, and

diagnostics in a simple manner.

LA

Abbreviation for Lenze Application block

Example: "LA_NCtrl" (block for the "Actuating drive speed" application)

Lenze setting

This setting is the default factory setting of the device.

LP

Abbreviation for Lenze Port block

Example: "LP_CanIn1" (CAN1 port block)

LS

Abbreviation for Lenze System block

Example: "LS_DigitalInput" (system block for digital input signals)

MCI

Abbreviation for Motionbus Communication Interface (fieldbus interface)

The Inverter Drives 8400 can accommodate plug-in communication modules and can

therefore take part in the data transfer of an existing fieldbus system.

Fieldbus interface (MCI)

Port block

Block for implementing the process data transfer via a fieldbus
PROFIBUS® (Process Field Bus) is fieldbus system used worldwide for automating machines

and production plants.

PROFIBUS® is a registered trademark and patented technology licensed by the user

organisation PROFIBUS & PROFINET International (PI).
PROFINET® (Process Field Network) is a real-time capable fieldbus system based on Ethernet.

PROFINET® is a registered trademark and patented technology licensed by the user

organisation PROFIBUS & PROFINET International (PI).

PSM

Abbreviation for permanently excited synchronous motor

QSP

Abbreviation for quick stop

SC

Abbreviation for Servo Control

Service brake

The service brake serves to shutdown rotary or translatory masses in motion in a controlled

manner. The energy to be dissipated in this process is produced in the form of friction

energy. Unlike emergency braking, this process is a regular and recurring operating mode.

SLPSM

Abbreviation for sensorless control of synchronous motors

SLVC

Abbreviation for SensorLess Vector Control

Subcode

If a code contains several parameters, these are stored in "subcodes".

This Manual uses a slash "/" as a separator between code and subcode (e.g. "C00118/3").

The term is usually called "subindex".

System block

System blocks provide interfaces to basic functions, to "free codes" and to the hardware of

the controller in the FB editor of the »Engineer« (e.g. to the digital inputs). Each system block

is only available once.

System blocks

USB diagnostic

adapter

The USB diagnostic adapter is used for the operation, parameterisation, and diagnostics of

the controller. Data are exchanged between the PC (USB connection) and the controller

(diagnostic interface on the front) via the diagnostic adapter. Order designation: E94AZCUS

VFCplus

Abbreviation for Voltage Frequency Control

Term

Meaning

Advertising