3commissioning – Lenze 8400 HighLine User Manual

Page 77

Advertising
background image

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

77

3

Commissioning

3.8

Commissioning of the "Table positioning" technology application

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

3. Set the profile parameters:

4. After entering the profile, click the Back button to change back to the OverviewSignal flow

dialog level.

Related topics:

Touch probe detection

( 353)

Operating mode change with profile number

( 518)

Positioning

( 575)

Parameter

Lenze setting

Info

Value Unit

Profile x: Mode

(

C01300/x

)

absolute

(shortest way)t

Selection of the way in which positioning is to be carried

out.

Positioning modes ( 582)

Profile x: Position

(

C01301/x

)

360.0000 unit

Target position or distance to be traversed.

Profile x: Speed

(

C01302/x

)

360.0000 unit/s

Maximum speed at which the target is to be

approached.

Profile x: Acceleration

(

C01303/x

)

720.0000 unit/s

2

Stipulation of the change in speed at which maximum

acceleration is to take place.

Profile x: Deceleration

(

C01304/x

)

720.0000 unit/s

2

Stipulation of the change in speed at which maximum

deceleration to a standstill is to take place.

Profile x: S-ramp time

(

C01306/x

)

0.000 s

Due to stipulation of an S-ramp time for a profile, the

profile is executed with S-shaped ramps, i.e.

acceleration and braking processes are initiated

smoothly in order to reduce jerk and thus the stress on

the drive components.

Profile x: Final speed

(

C01305/x

)

0.0000 unit/s

This specifies the speed at which the drive is to start the

next profile after reaching the target position.

Profile x: Sequence profile

(

C01307/x

)

0

Optional: Sequence profile for profile linkage /

following block control.

After execution of the profile (target position reached),

the set following (subsequent) profile is started

automatically. In this way, profile chains can be

stipulated without additional control processes.

Profile x: TP profile

(

C01308/x

)

0

Optional: Profile number of the profile (1 … 15) that is to

be executed after a touch probe has been detected.

• If "0" is set, there will be no profile stepping through

touch probe.

• Only relevant for positioning modes with touch-

probe.

Profile x: TP source

(

C01308/x

)

TP-DigIn3

Optional: Selection of the signal source for touch probe

detection.

• Only relevant for positioning modes with touch-

probe.

Advertising