I/O terminals

6.3

Analog terminals

346

Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

6.3.1

Parameterising analog input

By clicking on the

button on the Terminal assignment tab, you reach the parameterising

dialog for the corresponding analog input:

Short overview of parameters for the analog inputs:

Parameter

Info

Lenze setting

Value Unit

Analog input 1

C00034/1

AIN1: Config.

0: -10V..+10V

C00026/1

AIN1: Offset

0.00 %

C00027/1

AIN1: Gain

1.0000

C00028/1

AIN1: Input voltage

- V

C00029/1

AIN1: Input current

- mA

C00033/1

AIN1: Output value (to application)

- %

C00440/1

PT1 rounding AnalogIn1

10 ms

C00598/1

Resp. to open circuit AIN1

3: TroubleQuickStop

Analog input 2

C00034/2

AIN2: Config.

0: -10V..+10V

C00026/2

AIN2: Offset

0.00 %

C00027/2

AIN2: Gain

1.0000

C00028/2

AIN2: Input voltage

- V

C00029/2

AIN2: Input current

- mA

C00033/2

AIN2: Output value (to application)

- %

C00440/2

PT1 rounding AnalogIn2

10 ms

C00598/2

Resp. to open circuit AIN2

3: TroubleQuickStop